<ArticleTitle>NONDESTRUCTIVE EVALUATION OF MECHANICAL PROPERTIES OF DUCTILE CAST IRON PARTS USING EDDY CURRENT SIGNALS</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>439</FirstPage>
			<LastPage>443</LastPage>
			<ELocationID EIdType="pii">2507</ELocationID>
			
<ELocationID EIdType="doi">10.22099/ijstm.2014.2507</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2011</Year>
					<Month>08</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		<Abstract>The present research investigates improvement of Eddy Current (EC) technique as a&lt;br /&gt;nondestructive method for measurement of ductile cast iron microstructural and mechanical&lt;br /&gt;characteristics. Six samples of heat treated ductile cast iron have been selected to study the&lt;br /&gt;relations between pearlite content and EC outputs. These outputs include voltage and normalized&lt;br /&gt;impedance as well as calculated parameters of harmonic analysis. Furthermore, correlation&lt;br /&gt;between mechanical properties such as hardness, yield strength and ultimate tensile strength in&lt;br /&gt;samples containing different ferrite-pearlite matrices and the magnetic responses has also been&lt;br /&gt;found. High correlation coefficients of the relations indicate an acceptable level of accuracy in&lt;br /&gt;comparison with destructive method.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Nondestructive evaluation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">eddy current</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ductile cast iron</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Mechanical properties</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ijstm.shirazu.ac.ir/article_2507_d04a1f84042f242daf2ca3f407280df3.pdf</ArchiveCopySource>
</Article>
</ArticleSet>